Windhaber, J; Steinbauer, M; Holter, M; Wieland, A; Kogler, K; Riedl, R; Schober, P; Castellani, C; Singer, G; Till, H.
Bicycle spiroergometry: comparison of standardized examination protocols for adolescents: is it necessary to define own standard values for each protocol?
Eur J Appl Physiol. 2021; 121(6):1783-1794
Doi: 10.1007/s00421-021-04601-y
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Windhaber Jana Maria
- Co-authors Med Uni Graz
-
Castellani Christoph
-
Holter Magdalena
-
Riedl Regina
-
Schober Peter
-
Singer Georg
-
Till Holger
-
Wieland Annemarie
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- PURPOSE: To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol. METHODS: One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the two tests was performed based on our institutional weight-adapted protocol (P0). The other test was performed based on one out of four exercise protocols widely used for children and adolescents (P1, 2, 3 or 4) with 30 persons each. The two tests were performed in a random order. Routine parameters of cardiopulmonary exercise tests (CPET) such as VO2peak, maximum power, O2 pulse, OUES, VE/VCO2 slope as well as ventilatory and lactate thresholds were investigated. Agreement between protocols was evaluated by Bland-Altman analysis, coefficients of variation (CV) and intra-class correlation coefficients (ICC). RESULTS: None of the CPET parameters were significantly different between P0 and P1, 2, 3 or 4. For most of the parameters, low biases between P0 and P1-P4 were found and 95% confidence intervalls were narrow. CV and ICC values largely corresponded to well-defined analytical goals (CV < 10% and ICC > 0.9). Only maximal power (Pmax) showed differences in size and drift of the bias depending on the length of the step duration of the protocols. CONCLUSION: Comparability between examination protocols has been shown for CPET parameters independent on step duration. Protocol-dependent standard values do not appear to be necessary. Only Pmax is dependent on the step duration, but in most cases, this has no significant influence on the fitness assessment.
- Find related publications in this database (Keywords)
-
Spiroergometry
-
Adolescents
-
Examination protocols
-
VO(2)peak
-
Maximal power
-
O-2 pulse
-
OUES
-
Ventilatory threshold
-
Lactate threshold