Spearman, JV; Meinel, FG; Schoepf, UJ; Apfaltrer, P; Silverman, JR; Krazinski, AW; Canstein, C; De Cecco, CN; Costello, P; Geyer, LL.
Automated quantification of epicardial adipose tissue using CT angiography: evaluation of a prototype software.
Eur Radiol. 2014; 24(2): 519-526. Doi: 10.1007/s00330-013-3052-2
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Apfaltrer Paul
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. • Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. • The novel software prototype automates measurement of epicardial fat volume with good accuracy. • This novel approach is less time-consuming and could be incorporated into clinical workflow.
Find related publications in this database (using NLM MeSH Indexing)
Adipose Tissue - diagnostic imaging
Coronary Angiography - methods
Coronary Artery Disease - diagnostic imaging
Female -
Humans -
Imaging, Three-Dimensional - methods
Male -
Middle Aged -
Observer Variation -
Pericardium - diagnostic imaging
Radiographic Image Interpretation, Computer-Assisted - methods
Reproducibility of Results -
Retrospective Studies -
Software -
Software Design -
Tomography, X-Ray Computed - methods

Find related publications in this database (Keywords)
Epicardial adipose tissue
Cardiac computed tomography
Prototype
Atherosclerosis
Cardiovascular risk factor
© Med Uni Graz Impressum