Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Sudarski, S; Apfaltrer, P; Nance, JW; Schneider, D; Meyer, M; Schoenberg, SO; Fink, C; Henzler, T.
Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging.
Eur J Radiol. 2013; 82(10):e574-e581 Doi: 10.1016/j.ejrad.2013.04.040
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Apfaltrer Paul
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 ± 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 ± 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p>0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p<0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p<0.05) compared to PEIs at equal noise levels (+18% on average; all p>0.05) and equal or higher SNR (+49% on average; p<0.01-0.35). Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Find related publications in this database (using NLM MeSH Indexing)
Abdomen - blood supply
Aged -
Aged, 80 and over -
Algorithms -
Angiography - methods
Aortography - methods
Female -
Humans -
Lower Extremity - blood supply
Lower Extremity - diagnostic imaging
Male -
Middle Aged -
Radiographic Image Enhancement - methods
Radiography, Abdominal - methods
Radiography, Dual-Energy Scanned Projection - methods
Reproducibility of Results -
Sensitivity and Specificity -
Tomography, X-Ray Computed - methods

Find related publications in this database (Keywords)
CT angiography
Dual-source CT
Dual-energy CT
Monoenergetic Image quality
© Med Uni GrazImprint