Hajnsek, M; Nacht, B; Sax, S; List, E; Klimant, I; Sinner, F.
Single-port glucose monitoring with simultaneous insulin infusion.
Biomed Tech (Berl). 2013; 58 Suppl 1(12):
Doi: 10.1515/bmt-2013-4144
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Sinner Frank Michael
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- We present a novel single-port continuous glucose monitoring system that simultaneously performs continuous glucose monitoring in subcutaneous tissue and insulin infusion. The luminescence based glucose sensor is applied on commercial insulin infusion catheters and is read-out transcutaneously by an optical module attached to the skin. In-vitro and in-vivo evaluation results demonstrate a good proof of concept with median absolute relative error values in the range of 20%.
- Find related publications in this database (Keywords)
-
glucose monitoring
-
optical
-
single-port
-
insulin infusion
-