Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Seifnaraghi, N; de, Gelidi, S; Nordebo, S; Kallio, M; Frerichs, I; Tizzard, A; Suo-Palosaari, M; Sophocleous, L; van, Kaam, AH; Sorantin, E; Demosthenous, A; Bayford, RH.
Model Selection Based Algorithm in Neonatal Chest EIT.
IEEE Trans Biomed Eng. 2021; 68(9):2752-2763 Doi: 10.1109/TBME.2021.3053463
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Sorantin Erich
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
This paper presents a new method for selecting a patient specific forward model to compensate for anatomical variations in electrical impedance tomography (EIT) monitoring of neonates. The method uses a combination of shape sensors and absolute reconstruction. It takes advantage of a probabilistic approach which automatically selects the best estimated forward model fit from pre-stored library models. Absolute/static image reconstruction is performed as the core of the posterior probability calculations. The validity and reliability of the algorithm in detecting a suitable model in the presence of measurement noise is studied with simulated and measured data from 11 patients. The paper also demonstrates the potential improvements on the clinical parameters extracted from EIT images by considering a unique case study with a neonate patient undergoing computed tomography imaging as clinical indication prior to EIT monitoring. Two well-known image reconstruction techniques, namely GREIT and tSVD, are implemented to create the final tidal images. The impacts of appropriate model selection on the clinical extracted parameters such as center of ventilation and silent spaces are investigated. The results show significant improvements to the final reconstructed images and more importantly to the clinical EIT parameters extracted from the images that are crucial for decision-making and further interventions.
Find related publications in this database (using NLM MeSH Indexing)
Algorithms - administration & dosage
Electric Impedance - administration & dosage
Humans - administration & dosage
Image Processing, Computer-Assisted - administration & dosage
Infant, Newborn - administration & dosage
Reproducibility of Results - administration & dosage
Tomography - administration & dosage

Find related publications in this database (Keywords)
Tomography
Pediatrics
Electrodes
Imaging
Conductivity
Image reconstruction
Lung
Electrical impedance tomography
model selection
neonatal chest EIT
patient-specific prior model
thorax modelling
© Med Uni Graz Impressum