Zabotti, A; Zandonella Callegher, S; Tullio, A; Vukicevic, A; Hocevar, A; Milic, V; Cafaro, G; Carotti, M; Delli, K; De Lucia, O; Ernst, D; Ferro, F; Gattamelata, A; Germanò, G; Giovannini, I; Hammenfors, D; Jonsson, MV; Jousse-Joulin, S; Macchioni, P; Parisi, S; Perricone, C; Stradner, MH; Filipovic, N; Tzioufas, AG; Valent, F; De Vita, S.
Salivary Gland Ultrasonography in Sjögren's Syndrome: A European Multicenter Reliability Exercise for the HarmonicSS Project.
Front Med (Lausanne). 2020; 7: 581248-581248. Doi: 10.3389/fmed.2020.581248 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-authors Med Uni Graz
Stradner Martin Helmut
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Objectives: Salivary gland ultrasonography (SGUS) is increasingly applied for the management of primary Sjögren's syndrome (pSS). This study aims to: (i) compare the reliability between two SGUS scores; (ii) test the reliability among sonographers with different levels of experience. Methods: In the reliability exercise, two four-grade semi-quantitative SGUS scoring systems, namely De Vita et al. and OMERACT, were tested. The sonographers involved in work-package 7 of the HarmonicSS project from nine countries in Europe were invited to participate. Different levels of sonographers were identified on the basis of their SGUS experience and of the knowledge of the tested scores. A dedicated atlas was used as support for SGUS scoring. Results: Twenty sonographers participated in the two rounds of the reliability exercise. The intra-rater reliability for both scores was almost perfect, with a Light's kappa of 0.86 for the De Vita et al. score and 0.87 for the OMERACT score. The inter-rater reliability for the De Vita et al. and the OMERACT score was substantial with Light's Kappa of 0.75 and 0.77, respectively. Furthermore, no significant difference was noticed among sonographers with different levels of experience. Conclusion: The two tested SGUS scores are reliable for the evaluation of major salivary glands in pSS, and even less-expert sonographers could be reliable if adequately instructed. Copyright © 2020 Zabotti, Zandonella Callegher, Tullio, Vukicevic, Hocevar, Milic, Cafaro, Carotti, Delli, De Lucia, Ernst, Ferro, Gattamelata, Germanò, Giovannini, Hammenfors, Jonsson, Jousse-Joulin, Macchioni, Parisi, Perricone, Stradner, Filipovic, Tzioufas, Valent and De Vita.

Find related publications in this database (Keywords)
Sjö
gren&apos
s syndrome
scoring system
classification criteria
reliability exercise
salivary gland ultrasonography
© Med Uni GrazImprint