Automated mitral valve vortex ring extraction from 4D-flow MRI.
Magn Reson Med. 2020; 84(6):3396-3408 Doi: 10.1002/mrm.28361 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Kräuter Corina
Reiter Ursula
Co-Autor*innen der Med Uni Graz
Fuchsjäger Michael
Reiter Clemens
Reiter Gert
Schmidt Albrecht
Stollberger Rudolf
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
PURPOSE: To present and validate a method for automated extraction and analysis of the temporal evolution of the mitral valve (MV) vortex ring from MR 4D-flow data. METHODS: The proposed algorithm uses the divergence-free part of the velocity vector field for Q criterion-based identification and tracking of MV vortex ring core and region within the left ventricle (LV). The 4D-flow data of 20 subjects (10 healthy controls, 10 patients with ischemic heart disease) were used to validate the algorithm against visual analysis as well as to assess the method's sensitivity to manual LV segmentation. Quantitative MV vortex ring parameters were analyzed with respect to both their differences between healthy subjects and patients and their correlation with transmitral peak velocities. RESULTS: The algorithm successfully extracted MV vortex rings throughout the entire cardiac cycle, which agreed substantially with visual analysis (Cohen's kappa = 0.77). Furthermore, vortex cores and regions were robustly detected even if a static end-diastolic LV segmentation mask was applied to all frames (Dice coefficients 0.82 ± 0.08 and 0.94 ± 0.02 for core and region, respectively). Early diastolic MV vortex ring vorticity, kinetic energy and circularity index differed significantly between healthy controls and patients. In contrast to vortex shape parameters, vorticity and kinetic energy correlated strongly with transmitral peak velocities. CONCLUSION: An automated method for temporal MV vortex ring extraction demonstrating robustness with respect to LV segmentation strategies is introduced. Quantitative vortex parameter analysis indicates importance of the MV vortex ring for LV diastolic (dys)function.
Find related publications in this database (using NLM MeSH Indexing)
Algorithms - administration & dosage
Blood Flow Velocity - administration & dosage
Diastole - administration & dosage
Heart Ventricles - diagnostic imaging
Humans - administration & dosage
Magnetic Resonance Imaging - administration & dosage
Mitral Valve - diagnostic imaging
Ventricular Function, Left - administration & dosage

Find related publications in this database (Keywords)
4D-flow
blood flow
left ventricle
mitral valve vortex ring
Q criterion
vortex parameter
© Med Uni Graz Impressum