Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Zeller, T; Micari, A; Scheinert, D; Baumgartner, I; Bosiers, M; Vermassen, FEG; Banyai, M; Shishehbor, MH; Wang, H; Brodmann, M; IN.PACT DEEP Trial Investigators.
The IN.PACT DEEP Clinical Drug-Coated Balloon Trial: 5-Year Outcomes.
JACC Cardiovasc Interv. 2020; 13(4):431-443 Doi: 10.1016/j.jcin.2019.10.059 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Brodmann Marianne
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The goal of this study was to evaluate the 5-year follow-up data of the IN.PACT DEEP (Randomized IN.PACT Amphirion Drug-Coated Balloon [DCB] vs. Standard Percutaneous Transluminal Angioplasty [PTA] for the Treatment of Below-the-Knee Critical Limb Ischemia [CLI]) trial. Initial studies from randomized controlled trials have shown comparable short-term outcomes of DCB angioplasty versus PTA in patients with CLI with infrapopliteal disease. However, the long-term safety and effectiveness of DCB angioplasty remain unknown in this patient population. IN.PACT DEEP was an independently adjudicated prospective, multicenter, randomized controlled trial that enrolled 358 subjects with CLI. Subjects were randomized 2:1 to DCB angioplasty or PTA. Assessments through 5 years included freedom from clinically driven target lesion revascularization, amputation, and all-cause death. Additional assessments were conducted to identify risk factors for death and major amputation, including paclitaxel dose tercile. Freedom from clinically driven target lesion revascularization through 5 years was 70.9% and 76.0% (log-rank p = 0.406), and the incidence of the safety composite endpoint was 59.8% and 57.5% (log-rank p = 0.309) in the DCB angioplasty and PTA groups, respectively. The rate of major amputation was 15.4% for DCB angioplasty compared with 10.6% for PTA (log-rank p = 0.108). Given the recent concern regarding a late mortality signal in patients treated with paclitaxel-coated devices, additional analyses from this study showed no increase in all-cause mortality with DCB angioplasty (39.4%) compared with PTA (44.9%) (log-rank p = 0.727). Predictors of mortality included age, Rutherford category >4, and previous revascularization but not paclitaxel by dose tercile. Tibial artery revascularization in patients with CLI using DCB angioplasty resulted in comparable long-term safety and effectiveness as PTA. Paclitaxel exposure was not related to increased risk for amputation or all-cause mortality at 5-year follow-up. (Study of IN.PACT Amphirion™ Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733). Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.
Find related publications in this database (using NLM MeSH Indexing)
Aged -
Aged, 80 and over -
Amputation -
Angioplasty, Balloon - adverse effects
Angioplasty, Balloon - instrumentation
Angioplasty, Balloon - mortality
Cardiovascular Agents - administration & dosage
Cardiovascular Agents - adverse effects
Coated Materials, Biocompatible -
Critical Illness -
Equipment Design -
Equipment Design -
Female -
Humans -
Ischemia - diagnostic imaging
Ischemia - mortality
Ischemia - physiopathology
Ischemia - therapy
Limb Salvage -
Male -
Middle Aged -
Paclitaxel - administration & dosage
Paclitaxel - adverse effects
Peripheral Arterial Disease - diagnostic imaging
Peripheral Arterial Disease - mortality
Peripheral Arterial Disease - physiopathology
Peripheral Arterial Disease - therapy
Prospective Studies -
Recurrence -
Risk Factors -
Time Factors -
Treatment Outcome -
Vascular Patency -

Find related publications in this database (Keywords)
amputation
CD-TLR
drug-coated balloon
infrapopliteal
IN.PACT DEEP
mortality
paclitaxel
© Med Uni GrazImprint