Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Oettinger, V; Kaier, K; Heidt, T; Hortmann, M; Wolf, D; Zirlik, A; Zehender, M; Bode, C; von Zur Mühlen, C; Stachon, P.
Outcomes of transcatheter aortic valve implantations in high-volume or low-volume centres in Germany.
Heart. 2020; 106(20):1604-1608 Doi: 10.1136/heartjnl-2019-316058
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Zirlik Andreas
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Transcatheter aortic valve implantation (TAVI) is the most common aortic valve replacement in Germany. Since 2015, to ensure high-quality procedures, hospitals in Germany and other countries that meet the minimum requirement of 50 interventions per centre are being certified to perform TAVI. This study analyses the impact of these requirements on case number and in-hospital outcomes. All isolated TAVI procedures and in-hospital outcomes between 2008 and 2016 were identified by International Classification of Diseases (ICD) and the German Operation and Procedure Classification codes. 73 467 isolated transfemoral and transapical TAVI procedures were performed in Germany between 2008 and 2016. During this period, the number of TAVI procedures per year rose steeply, whereas the overall rates of hospital mortality and complications declined. In 2008, the majority of procedures were performed in hospitals with fewer than 50 cases per year (54.63%). Until 2014, the share of patients treated in low-volume centres constantly decreased to 5.35%. After the revision of recommendations, it further declined to 1.99%. In the 2 years after the introduction of the minimum requirements on case numbers, patients were at decreased risk for in-hospital mortality when treated in a high-volume centre (risk-adjusted OR 0.62, p=0.012). The risk for other in-hospital outcomes (stroke, permanent pacemaker implantation and bleeding events) did not differ after risk adjustment (p=0.346, p=0.142 and p=0.633). A minimum volume of 50 procedures per centre and year appears suitable to allow for sufficient routine and thus better in-hospital outcomes, while ensuring nationwide coverage of TAVI procedures. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.

Find related publications in this database (Keywords)
transcatheter valve interventions
valvular heart disease
aortic regurgitation
© Med Uni Graz Impressum