Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Nehrer, S; Ljuhar, R; Steindl, P; Simon, R; Maurer, D; Ljuhar, D; Bertalan, Z; Dimai, HP; Goetz, C; Paixao, T.
Automated Knee Osteoarthritis Assessment Increases Physicians' Agreement Rate and Accuracy: Data from the Osteoarthritis Initiative.
Cartilage. 2021; 13(1_suppl):957S-965S Doi: 10.1177/1947603519888793 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Dimai Hans Peter
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Objective. To assess the impact of a computerized system on physicians' accuracy and agreement rate, as compared with unaided diagnosis. Methods. A set of 124 unilateral knee radiographs from the Osteoarthritis Initiative (OAI) study were analyzed by a computerized method with regard to Kellgren-Lawrence (KL) grade, as well as joint space narrowing, osteophytes, and sclerosis Osteoarthritis Research Society International (OARSI) grades. Physicians scored all images, with regard to osteophytes, sclerosis, joint space narrowing OARSI grades and KL grade, in 2 modalities: through a plain radiograph (unaided) and a radiograph presented together with the report from the computer assisted detection system (aided). Intraclass correlation between the physicians was calculated for both modalities. Furthermore, physicians' performance was compared with the grading of the OAI study, and accuracy, sensitivity, and specificity were calculated in both modalities for each of the scored features. Results. Agreement rates for KL grade, sclerosis, and osteophyte OARSI grades, were statistically increased in the aided versus the unaided modality. Readings for joint space narrowing OARSI grade did not show a statistically difference between the 2 modalities. Readers' accuracy and specificity for KL grade >0, KL >1, sclerosis OARSI grade >0, and osteophyte OARSI grade >0 was significantly increased in the aided modality. Reader sensitivity was high in both modalities. Conclusions. These results show that the use of an automated knee OA software increases consistency between physicians when grading radiographic features of OA. The use of the software also increased accuracy measures as compared with the OAI study, mostly through increases in specificity.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Knee Joint - diagnostic imaging
Osteoarthritis, Knee - diagnostic imaging
Osteophyte - diagnostic imaging
Physicians - administration & dosage
Radiography - administration & dosage

Find related publications in this database (Keywords)
Kellgren-Lawrence
computer aided detection
reader study
artificial intelligence
© Med Uni Graz Impressum