Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Zajic, P; Heschl, S; Schörghuber, M; Srekl-Filzmaier, P; Stojakovic, T; Weixler, V; Zelzer, S; Amrein, K.
Vitamin D assessment in perioperative medicine and critical care : A prospective observational pilot study.
Wien Klin Wochenschr. 2021; 133(3-4):79-85 Doi: 10.1007/s00508-019-01584-x [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Zajic Paul
Co-Autor*innen der Med Uni Graz
Amrein Karin
Heschl Stefan
Schörghuber Michael
Srekl-Filzmaier Petra
Stojakovic Tatjana
Weixler Viktoria Heide-Marie
Zelzer Sieglinde
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
There is controversy about the impact of acute illness on vitamin D levels. This study was carried out to assess the influence of perioperative fluid loading on 25-hydroxy-vitamin D [25(OH)D] levels. The study evaluated the clinical utility of a commonly available chemiluminescence assay (ECLIA, IDS-iSYS) and liquid chromatography/mass spectrometry (LC-MS/MS) in the diagnosis of vitamin D deficiency in this setting. In this prospective observational pilot study in adult patients undergoing cardiovascular surgery on cardiopulmonary bypass (CPB), blood samples drawn at preoperative baseline (t1), after weaning from CPB (t2), on intensive care unit (ICU) admission (t3) and on the first (t4) and second (t5) postoperative days were analyzed. A total of 26 patients (130 samples) were included in this study. Fluid loading by CPB led to a median reduction of 25(OH)D by -22.6% (range -54.5% to -19.5%) between t1 and t2. Cohen's kappa (κ) for method agreement for vitamin D deficiency (tested cut-off values 20 ng/ml and 12 ng/ml), was κ = 0.291 (p < 0.001) and κ = 0.469 (p < 0.001), respectively. The mean difference between measurements by ECLIA and LC-MS/MS was 4.8 ng/ml (±5.7), Pearson's r for correlation was 0.73 (p < 0.001). The biologically inactive C3-epimer did not contribute to 25(OH)D levels assessed by LC-MS/MS. The 25(OH)D measurements by chemiluminescence assays can noticeably deviate from those measured by LC-MS/MS, which can be considered the unequivocal gold standard. These assays may still be acceptably reliable in the screening for vitamin D deficiency, especially in the setting of low vitamin D levels. Stricter definitions, e.g. serum 25(OH)D levels lower than 12 ng/ml, may be used to diagnose deficiency with low false positive rate. DRKS00009216, German Clinical Trials Registry ( www.drks.de ).
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Chromatography, Liquid -
Critical Care -
Humans -
Perioperative Medicine -
Pilot Projects -
Prospective Studies -
Tandem Mass Spectrometry -
Vitamin D -

Find related publications in this database (Keywords)
Vitamin D
Vitamin D deficiency
Critical care
Diagnosis
© Med Uni Graz Impressum