Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Moche, M; Busse, H; Futterer, JJ; Hinestrosa, CA; Seider, D; Brandmaier, P; Kolesnik, M; Jenniskens, S; Blanco, Sequeiros, R; Komar, G; Pollari, M; Eibisberger, M; Portugaller, HR; Voglreiter, P; Flanagan, R; Mariappan, P; Reinhardt, M.
Clinical evaluation of in silico planning and real-time simulation of hepatic radiofrequency ablation (ClinicIMPPACT Trial).
Eur Radiol. 2020; 30(2):934-942 Doi: 10.1007/s00330-019-06411-5
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Eibisberger Martin
Portugaller Rupert
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVES: To evaluate the accuracy and clinical integrability of a comprehensive simulation tool to plan and predict radiofrequency ablation (RFA) zones in liver tumors. METHODS: Forty-five patients with 51 malignant hepatic lesions of different origins were included in a prospective multicenter trial. Prior to CT-guided RFA, all patients underwent multiphase CT which included acquisitions for the assessment of liver perfusion. These data were used to generate a 3D model of the liver. The intra-procedural position of the RFA probe was determined by CT and semi-automatically registered to the 3D model. Size and shape of the simulated ablation zones were compared with those of the thermal ablation zones segmented in contrast-enhanced CT images 1 month after RFA; procedure time was compared with a historical control group. RESULTS: Simulated and segmented ablation zone volumes showed a significant correlation (ρ = 0.59, p < 0.0001) and no significant bias (Wilcoxon's Z = 0.68, p = 0.25). Representative measures of ablation zone comparison were as follows: average surface deviation (absolute average error, AAE) with 3.4 ± 1.7 mm, Dice similarity coefficient 0.62 ± 0.14, sensitivity 0.70 ± 0.21, and positive predictive value 0.66 ± 0. There was a moderate positive correlation between AAE and duration of the ablation (∆t; r = 0.37, p = 0.008). After adjustments for inter-individual differences in ∆t, liver perfusion, and prior transarterial chemoembolization procedures, ∆t was an independent predictor of AAE (ß = 0.03 mm/min, p = 0.01). Compared with a historical control group, the simulation added 3.5 ± 1.9 min to the procedure. CONCLUSION: The validated simulation tool showed acceptable speed and accuracy in predicting the size and shape of hepatic RFA ablation zones. Further randomized controlled trials are needed to evaluate to what extent this tool might improve patient outcomes. KEY POINTS: • More reliable, patient-specific intra-procedural estimation of the induced RFA ablation zones in the liver may lead to better planning of the safety margins around tumors. • Dedicated real-time simulation software to predict RFA-induced ablation zones in patients with liver malignancies has shown acceptable agreement with the follow-up results in a first prospective multicenter trial suggesting a randomized controlled clinical trial to evaluate potential outcome benefit for patients.
Find related publications in this database (using NLM MeSH Indexing)
Adolescent - administration & dosage
Adult - administration & dosage
Aged - administration & dosage
Carcinoma, Hepatocellular - pathology, surgery
Catheter Ablation - methods
Chemoembolization, Therapeutic - methods
Computer Simulation - administration & dosage
Female - administration & dosage
Humans - administration & dosage
Liver - pathology, surgery
Liver Neoplasms - pathology, surgery
Male - administration & dosage
Margins of Excision - administration & dosage
Middle Aged - administration & dosage
Patient Care Planning - administration & dosage
Prospective Studies - administration & dosage
Tomography, X-Ray Computed - administration & dosage
Young Adult - administration & dosage

Find related publications in this database (Keywords)
Radiofrequency ablation
Liver
Perfusion
Software
© Med Uni GrazImprint