Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Pagnesi, M; Kim, WK; Conradi, L; Barbanti, M; Stefanini, GG; Zeus, T; Pilgrim, T; Schofer, J; Zweiker, D; Testa, L; Taramasso, M; Hildick-Smith, D; Abizaid, A; Wolf, A; Van Mieghem, NM; Sedaghat, A; Wöhrle, J; Khogali, S; Van der Heyden, JAS; Webb, JG; Estévez-Loureiro, R; Mylotte, D; MacCarthy, P; Brugaletta, S; Hamm, CW; Bhadra, OD; Schäfer, U; Costa, G; Tamburino, C; Cannata, F; Reimers, B; Veulemans, V; Asami, M; Windecker, S; Eitan, A; Schmidt, A; Bianchi, G; Bedogni, F; Saccocci, M; Maisano, F; Alsanjari, O; Siqueira, D; Jensen, CJ; Naber, CK; Ziviello, F; Sinning, JM; Seeger, J; Rottbauer, W; Brouwer, J; Alenezi, A; Wood, DA; Tzalamouras, V; Regueiro, A; Colombo, A; Latib, A.
Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices: A Multicenter, Retrospective, Propensity-Matched Comparison of Evolut PRO Versus Acurate neo Transcatheter Heart Valves.
JACC Cardiovasc Interv. 2019; 12(5): 433-443. Doi: 10.1016/j.jcin.2018.11.036 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Schmidt Albrecht
Zweiker David
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices. Copyright © 2019. Published by Elsevier Inc.

Find related publications in this database (Keywords)
Acurate neo
Evolut PRO
self-expanding
TAVR
VARC-2
© Med Uni Graz Impressum