Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Berger, T; Weiss, G; Voetsch, A; Arnold, Z; Kreibich, M; Rylski, B; Krombholz-Reindl, P; Winkler, A; Mach, M; Geisler, D; Seitelberger, R; Siepe, M; Beyersdorf, F; Grabenwoeger, M; Czerny, M; Gottardi, R.
Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection†.
Eur J Cardiothorac Surg. 2019; 56(3):572-578
Doi: 10.1093/ejcts/ezz037
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Vötsch Andreas
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex™ hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection.
All consecutive patients [n = 88; median age 59 (49-67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex™ device was implanted in 55 patients and the E-vita Open graft in 33 patients.
Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex™ hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses.
In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.
© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
- Find related publications in this database (Keywords)
-
Frozen elephant trunk
-
Aortic dissection
-
False lumen thrombosis