Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Ansel, GM; Brodmann, M; Keirse, K; Micari, A; Jaff, MR; Rocha-Singh, K; Fernandez, EJ; Wang, H; Zeller, T; IN.PACT Global Study Investigators.
Drug-Coated Balloon Treatment of Femoropopliteal Lesions Typically Excluded From Clinical Trials: 12-Month Findings From the IN.PACT Global Study.
J Endovasc Ther. 2018; 25(6):673-682
Doi: 10.1177/1526602818803119
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Brodmann Marianne
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
To report a post hoc analysis comparing outcomes between subjects who would have been included in the IN.PACT SFA randomized controlled trial vs those who would have been excluded.
The 1406 subjects enrolled in the IN.PACT Global Study ( ClinicalTrials.gov identifier NCT01609296) were retrospectively assigned to a standard-use group (n=281) based on the inclusion and exclusion criteria from the randomized IN.PACT SFA trial; the remaining 1125 patients were assigned to the broader-use group. Freedom from clinically-driven target lesion revascularization (CD-TLR) was evaluated at 12 months. The composite primary safety endpoint was freedom from 30-day device- and procedure-related death plus freedom from 12-month target limb major amputation and clinically-driven target vessel revascularization (CD-TVR). Functional outcomes were evaluated with dedicated questionnaires.
Compared with the standard-use cohort, the broader-use lesions were longer, more calcified, and had more popliteal involvement, bilateral disease, and in-stent restenosis (p<0.001 for all). Freedom from 12-month CD-TLR by Kaplan-Meier analysis was 96.6% for the standard-use group and 91.6% for the broader-use group (p=0.005). The safety endpoint was 96.2% in the standard-use group and 91.0% in the broader-use group (p=0.003). The 12-month CD-TLR (3.4% standard-use vs 8.5% broader-use, p=0.004) and CD-TVR (4.2% standard-use vs 9.1% broader-use, p=0.008) were increased in the broader-use group. Twelve-month all-cause mortality was not increased (3.8% standard-use vs 3.4% broader-use, p=0.852).
Post hoc analysis of the IN.PACT Global Study of real-world patients demonstrated consistent outcomes with significant clinical improvement to 12 months in subjects with complex lesions typically excluded from a randomized controlled trial.
- Find related publications in this database (Keywords)
-
angioplasty
-
drug-coated balloon
-
femoropopliteal segment
-
peripheral artery disease
-
popliteal artery
-
superficial femoral artery
-
target lesion revascularization
-
stenting