Moser, O; Pandis, M; Aberer, F; Kojzar, H; Hochfellner, D; Elsayed, H; Motschnig, M; Augustin, T; Kreuzer, P; Pieber, TR; Sourij, H; Mader, JK.
A head-to-head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot.
Diabetes Obes Metab. 2019; 21(4):1043-1048
Doi: 10.1111/dom.13598
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Moser Othmar
-
Pandis Marlene
-
Sourij Harald
- Co-authors Med Uni Graz
-
Aberer Felix
-
Elsayed Hesham
-
Hochfellner Daniel
-
Kojzar Harald
-
Mader Julia
-
Pieber Thomas
-
Wimmer Melanie
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
To compare the performance of a professional continuous glucose monitoring (proCGM) and a personal continuous glucose monitoring (persCGM) system worn in parallel under standardized conditions in individuals with type 1 diabetes (T1D), two CGM systems (iPro2 - proCGM; Minimed 640G - persCGM) worn in parallel using the same sensor (Enlite 2) were compared. Ten people with T1D were included in this single-centre, open-label study in which CGM performance was evaluated. The study consisted of a 24-hours inpatient phase (meals, exercise, glycaemic challenges) and a 4-day home phase. Analyses included fulfilment of ISO 15197:2013 criteria, mean absolute relative difference (MARD), Parkes Error Grid and Bland-Altman plots. During the inpatient stay, ISO 15197:2013 criteria fulfilment was 58.4% (proCGM) and 57.8% (persCGM). At home, the systems met ISO 15197:2013 criteria by 66.5% (proCGM) and 65.3% (persCGM). No difference of MARD in inpatient phase (19.1 ± 16.7% vs. 19.0 ± 19.6; P = 0.83) and home phase (18.6 ± 26.8% vs. 17.4 ± 21.3%, P = 0.87) was observed. All sensors performed less accurately during hypoglycaemia. ProCGM and persCGM showed similar performance during daytime and night-time for the inpatient and the home phase. However, sensor performance was reduced during hypoglycaemia for both systems.
© 2018 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.
- Find related publications in this database (using NLM MeSH Indexing)
-
Adult -
-
Blood Glucose - metabolism
-
Blood Glucose Self-Monitoring - instrumentation
-
Diabetes Mellitus, Type 1 - drug therapy
-
Diabetes Mellitus, Type 1 - metabolism
-
Female -
-
Humans -
-
Hyperglycemia - diagnosis
-
Hyperglycemia - metabolism
-
Hypoglycemia - diagnosis
-
Hypoglycemia - metabolism
-
Hypoglycemic Agents - therapeutic use
-
Insulin - therapeutic use
-
Male -
-
Monitoring, Ambulatory - instrumentation
-
Monitoring, Physiologic - instrumentation
-
Young Adult -
- Find related publications in this database (Keywords)
-
clinical trial
-
continuous glucose monitoring (CGM)
-
hypoglycaemia
-
type 1 diabetes