Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Herrmann, M; Henneicke, H; Street, J; Modzelewski, J; Kalak, R; Buttgereit, F; Dunstan, CR; Zhou, H; Seibel, MJ.
The challenge of continuous exogenous glucocorticoid administration in mice.
Steroids. 2009; 74(2):245-249 Doi: 10.1016/j.steroids.2008.11.009
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Herrmann Markus
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Chronic administration of exogenous glucocorticoids is often required in experimental research. We compared the efficacy and reliability of three different methods of continuous glucocorticoid administration in mice. Male CD1 Swiss White mice aged 7-9 weeks received corticosterone (CS) or carrier by either subcutaneous (s.c.) injection (n=15), s.c. implantation of micro-osmotic pumps (n=20) or s.c. implantation of slow-release pellets (n=20). Serial blood samples were taken for the measurement of plasma CS and osteocalcin (OC). Bone structural parameters were analysed by micro-computed tomography (micro-CT) in animals treated via slow-release pellets for 4 weeks. Injection of CS (10 mg/kg) resulted in peak plasma CS levels of up to 2600 microg/L after 1 h, with levels returning to baseline within 4 h post-injection. Micro-osmotic pumps failed to consistently alter plasma CS levels and had variable effects on plasma OC levels. Implantation of 10 mg CS pellets induced hypercorticosteronemia within 24 h but levels returned to baseline within 7 days. Plasma OC levels fell rapidly on day 1 and remained suppressed until day 7. Weekly replacement of pellets maintained elevated plasma CS and suppressed plasma OC concentrations, and resulted in significant bone loss at the tibia and spine after 28 days. Once-weekly s.c. implantation of slow-release pellets to mice appears to result in relatively consistent plasma CS and OC levels with significant biological effects. However, at least in our hands, no method delivered CS at a constant rate and variability in plasma CS levels was pronounced.
Find related publications in this database (using NLM MeSH Indexing)
Animals -
Chronic Disease -
Corticosterone - administration & dosage
Corticosterone - toxicity
Drug Delivery Systems - methods
Drug Implants -
Glucocorticoids - administration & dosage
Glucocorticoids - toxicity
Injections, Subcutaneous -
Male -
Mice -
Osmosis -
Time Factors -

Find related publications in this database (Keywords)
Glucocorticoids
Corticosterone
Micro-osmotic pumps
Slow-release pellets
Injection
Mice
© Med Uni Graz Impressum