Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Husic, R; Lackner, A; Stradner, MH; Hermann, J; Dejaco, C.
Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands.
Rheumatology (Oxford). 2017; 56(8):1312-1319 Doi: 10.1093/rheumatology/kex153 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Dejaco Christian
Husic Rusmir
Co-Autor*innen der Med Uni Graz
Hermann Josef
Lackner Angelika
Stradner Martin Helmut
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. METHODS: A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. RESULTS: Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). CONCLUSION: In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines.
Find related publications in this database (using NLM MeSH Indexing)
Adult - administration & dosage
Aged - administration & dosage
Arthritis, Rheumatoid - diagnostic imaging
Cross-Sectional Studies - administration & dosage
Female - administration & dosage
Hand Joints - diagnostic imaging
Humans - administration & dosage
Imaging, Three-Dimensional - methods
Male - administration & dosage
Middle Aged - administration & dosage
Patient Positioning - methods
Sensitivity and Specificity - administration & dosage
Synovitis - diagnostic imaging
Ultrasonography, Doppler - methods
Wrist Joint - diagnostic imaging

Find related publications in this database (Keywords)
rheumatoid arthritis
hand
diagnostic imaging
ultrasonography
wrist
© Med Uni Graz Impressum