Burket, MW; Brodmann, M; Metzger, C; Tan, K; Jaff, MR.
Twelve-Month Results of the Nitinol Astron Stent in Iliac Artery Lesions.
J Vasc Interv Radiol. 2016; 27(11):1650-1656
Doi: 10.1016/j.jvir.2016.06.008
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Brodmann Marianne
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
To evaluate the safety and efficacy of a self-expanding bare-metal nitinol stent (Astron; BIOTRONIK AG, Bülach, Switzerland) for the treatment of atherosclerotic lesions in the common and external iliac arteries. This study tested the hypothesis that the major adverse event (MAE) rate at 12 months was less than or equal to a performance goal of 15%.
In a prospective study that began in November 2011, 161 patients with symptomatic iliac lesions were treated with an Astron stent in the United States, Canada, and Austria. The primary endpoint was a composite rate of procedure- and stent-related MAEs at 12 months that included 30-day mortality, clinically indicated target lesion revascularization (TLR), and index limb amputation.
The MAE rate at 12 months was 2.1% (3/146; [95% CI: 0.4% to 5.9%]; p < 0.001). The acute procedural success and 30-day clinical success outcomes were both 95% (153/161). The primary patency rate at 12 months was 89.8% (115/128). The comparison of baseline and 12-month Ankle Brachial Index (ABI) measurements showed a mean increase of 0.23 ± 0.19 (p < 0.001). The Walking Impairment Questionnaire (WIQ) PAD specific score, walking distance score, walking speed score and stair climbing score paired each showed a significant increase from baseline to 12 months (p<0.001).
The Astron stent system was shown to be safe and effective in the treatment of patients with atherosclerotic disease. The observed MAE rate met the pre-specified performance goal of 15%. The stent demonstrated a high 12-month primary patency rate and showed improvement in quality of life measures.
Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aged -
-
Alloys -
-
Ankle Brachial Index -
-
Austria -
-
Canada -
-
Constriction, Pathologic -
-
Endovascular Procedures - adverse effects
-
Endovascular Procedures - instrumentation
-
Exercise Test -
-
Exercise Tolerance -
-
Female -
-
Humans -
-
Iliac Artery - diagnostic imaging
-
Iliac Artery - physiopathology
-
Intermittent Claudication - diagnostic imaging
-
Intermittent Claudication - physiopathology
-
Intermittent Claudication - therapy
-
Limb Salvage -
-
Male -
-
Middle Aged -
-
Peripheral Arterial Disease - diagnostic imaging
-
Peripheral Arterial Disease - physiopathology
-
Peripheral Arterial Disease - therapy
-
Prospective Studies -
-
Prosthesis Design -
-
Quality of Life -
-
Recovery of Function -
-
Registries -
-
Self Expandable Metallic Stents -
-
Surveys and Questionnaires -
-
Time Factors -
-
Treatment Outcome -
-
United States -
-
Vascular Patency -
-
Walking -