Ewers, R; Seemann, R; Krennmair, G; Schicho, K; Kurdi, AO; Kirsch, A; Reichwein, A.
Planning implants crown down--a systematic quality control for proof of concept.
J Oral Maxillofac Surg. 2010; 68(11): 2868-2878.
Doi: 10.1016/j.joms.2009.03.024
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Schicho Kurt
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
We evaluated an innovative approach for conventional surgical or transmucosal implantation applying backward planning with bone oriented crown down implant positions, followed by immediate restoration.
Our workflow combined computer-assisted preoperative planning with the well-known intraoperative handling of surgical templates. To guarantee optimal accuracy, the complete process was bone borne, not soft tissue borne. Furthermore, in this concept, the definite prosthesis was manufactured on a plaster cast and fixed with technical implants inserted into the model using the same drilling template applied for intraoperative guidance of the drill. This bone-based workflow avoids the accumulation of errors throughout all steps of the treatment. In the present study, we have provided a concise quantitative quality control using 4 in vivo implants. This goal was accomplished by image matching of the preoperative plan with the corresponding postoperative computed tomography scan, applying descriptive statistics, the 1-sample t test, and the Student t test.
Statistical evaluation showed that the bone-borne drilling template provides sufficient accuracy for immediate restoration with the definite prosthesis at the end of the operation. Deviation in the apex plane was 0.8 ± 0.42 mm, with 0.33 at the maximum. The angular deviation was 3.18° ± 0.78°.
Our workflow is a promising approach with respect to handling, accuracy, and intraoperative safety.
Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
- Find related publications in this database (using NLM MeSH Indexing)
-
Dental Abutments -
-
Dental Implantation, Endosseous - instrumentation Dental Implantation, Endosseous - methods Dental Implantation, Endosseous - standards
-
Dental Implants - standards
-
Dental Models -
-
Dental Prosthesis Design - standards
-
Dental Prosthesis, Implant-Supported -
-
Humans -
-
Image Processing, Computer-Assisted -
-
Intraoperative Care - instrumentation
-
Patient Care Planning - standards
-
Quality Control -
-
Software -
-
Tomography, X-Ray Computed -