Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Rosado, E; Riccabona, M.
Off-Label Use of Ultrasound Contrast Agents for Intravenous Applications in Children: Analysis of the Existing Literature.
J Ultrasound Med. 2016; 35(3):487-496 Doi: 10.7863/ultra.15.02030 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Riccabona Michael
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The purpose of this study was to collect and analyze the published data related to intravenous (IV) use of ultrasound (US) contrast agents in children. We searched the literature to collect all of the published studies reporting the IV administration of a second-generation US contrast agent in children. We analyzed 9 case series and 5 case reports, as well as 5 individual cases, of pediatric contrast-enhanced US use reported in a study group that also included adults. We found that 502 children underwent contrast-enhanced US examinations (mean age, 9.7 years; range, 1 day-18 years). Most patients (89%) were injected with the sulfur hexafluoride contrast agent SonoVue (Bracco SpA, Milan, Italy). The mean dose used was 1.5 mL (range, 0.1-9.6 mL). Only 10 patients (2%) had adverse reactions related to the contrast agent administration: 1 life-threatening anaphylactic shock and 9 mild transitory adverse effects. We additionally found 38 papers in which the study groups included at least 1 child; thus, we obtained a total of 540 reported cases of off-label use of IV US contrast agents in children. The most frequent target organ was the liver, and most indications were related to space-occupying lesion characterization and abdominal evaluations after blunt trauma. Some studies also evaluated the diagnostic performance of contrast-enhanced US in different clinical scenarios and found very good accuracy. Concordance between contrast-enhanced US imaging and the respective reference-standard imaging methods ranged between 83% and 100% in different studies. Our results support the idea that the IV use of US contrast agents in children is safe, feasible, diagnostically robust, and effective. © 2016 by the American Institute of Ultrasound in Medicine.
Find related publications in this database (using NLM MeSH Indexing)
Adolescent -
Child -
Child, Preschool -
Contrast Media - administration & dosage
Drug-Related Side Effects and Adverse Reactions - epidemiology
Female -
Humans -
Image Enhancement - methods
Incidence -
Infant -
Infant, Newborn -
Injections, Intravenous - statistics & numerical data
Male -
Off-Label Use - statistics & numerical data
Phospholipids - administration & dosage
Risk Assessment -
Sulfur Hexafluoride - administration & dosage
Ultrasonography - methods
Ultrasonography - statistics & numerical data
Utilization Review -

Find related publications in this database (Keywords)
children
contrast-enhanced ultrasound
intravenous
pediatrics
pediatric ultrasound
safety
ultrasound contrast agents
© Med Uni Graz Impressum