Phillipos, E; Solevåg, AL; Pichler, G; Aziz, K; van Os, S; O'Reilly, M; Cheung, PY; Schmölzer, GM.
Heart Rate Assessment Immediately after Birth.
Neonatology. 2016; 109(2):130-138 Doi: 10.1159/000441940 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Schmölzer Georg
Co-authors Med Uni Graz
Pichler Gerhard
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.
Find related publications in this database (using NLM MeSH Indexing)
Heart Function Tests - methods
Heart Rate -
Humans -
Infant, Newborn - physiology
Neonatal Screening -
Resuscitation -

Find related publications in this database (Keywords)
Infants
Newborn
Neonatal resuscitation
Heart rate
Pulse oximetry
Electrocardiogram
Auscultation
Palpation
Doppler ultrasound
Photoplethysmography
© Med Uni GrazImprint