Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Ponschab, M; Schlimp, CJ; Zipperle, J; Gabriel, C; Süssner, S; Cadamuro, J; Gratz, J; Redl, H; Schöchl, H.
Platelet function in reconstituted whole blood variants: An observational study over 5 days of storage time.
J Trauma Acute Care Surg. 2015; 79(5):797-804 Doi: 10.1097/TA.0000000000000852
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
GABRIEL Christian
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Platelet concentrates (PCs) are usually stored at room temperature under constant gentle agitation. Risk of bacterial contamination limits maximum storage time to 5 days. The objective of the study was to investigate platelet function with regard to storage time in different reconstituted whole blood (RWB) variants. Donated apheresis PCs were stored at 22°C over 5 days. To obtain RWB, apheresis PCs were mixed with plasma-free packed red blood cells (RBCs) and either prethawed fresh frozen plasma (PT) or solvent-detergent plasma (SD) [1:1:1 ratio], or with leukocyte- and platelet-depleted whole blood (LD-WB) as control. Platelet function in RWB variants was assessed by impedance aggregometry (Multiplate) on Days 0, 1, 3, and 5 following platelet donation. Platelet aggregometry did not reach the lower limits determined from healthy volunteers in any of the RWB variants. Platelet aggregability measured by ASPI test, ADP test, and COL test declined over storage time in all RWB variants. No differences were observed in the TRAP test. At most measurement time points, LD-RWB provided significantly higher platelet aggregability compared with SD-RWB and PT-RWB (p < 0.01). SD-RWB demonstrated higher platelet aggregability on Day 0 in the ASPI test, ADP test, and TRAP test compared with PT-RWB. Apheresis PCs stored for 5 days at 22°C demonstrated reduced platelet aggregability, as measured by multiple electrode aggregometry when mixed with RBCs and plasma. As platelet aggregation in LD-RWB was superior compared with SD-RWB and PT-RWB variants, it might be possible that additives in RBCs or plasma are responsible for the observed depressed platelet function. Critical evaluation of current massive transfusion recommendations proposing early platelet transfusion is indicated.
Find related publications in this database (using NLM MeSH Indexing)
Analysis of Variance -
Blood Banks -
Blood Platelets - physiology
Blood Preservation - methods
Blood Safety -
Female -
Humans -
Male -
Platelet Aggregation - physiology
Platelet Function Tests -
Platelet Transfusion -
Risk Assessment -
Sensitivity and Specificity -
Thrombelastography - methods
Time Factors -
Trauma Severity Indices -
Wounds and Injuries - diagnosis
Wounds and Injuries - therapy

Find related publications in this database (Keywords)
Platelet storage
platelet aggregation
massive transfusion
reconstituted blood
© Med Uni Graz Impressum