Gewählte Publikation:
SHR
Neuro
Krebs
Kardio
Lipid
Stoffw
Microb
Schaden, E; Kimberger, O; Kraincuk, P; Baron, DM; Metnitz, PG; Kozek-Langenecker, S.
Perioperative treatment algorithm for bleeding burn patients reduces allogeneic blood product requirements.
Br J Anaesth. 2012; 109(3):376-381
Doi: 10.1093/bja/aes186
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Metnitz Philipp
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
-
Surgical excision of burn wounds is often associated with severe bleeding. Timely and targeted correction of coagulopathy reduces transfusion requirements and improves survival in trauma victims. We hypothesized that rapid correction of coagulopathy after a treatment algorithm based on point-of-care viscoelastic coagulation testing would decrease allogeneic blood product transfusions during surgical excision of burn wounds.
Thirty consecutive patients undergoing surgical excision of burn wounds were enrolled into this prospective, randomized, controlled, single-centre study. In the control group, coagulation management was performed according to the clinicians' discretion. For the algorithm group, we standardized treatment based on the Austrian recommendation for the management of trauma-induced coagulopathy using point-of-care rotational thromboelastometry (ROTEM(®)). The main outcome parameter was the cumulative number of allogeneic blood units transfused on the day of surgery.
The difference between the groups regarding the cumulative use of allogeneic blood products was highly significant with 3.0 (1.3-5.5) blood products in the algorithm group compared with 9.0 (6.0-12.3) in the control group [median (inter-quartile range); P=0.002]. No plasma was administered in the algorithm group compared with 5.0 (1.5-7.5) units overall in the control group (P<0.001). Fibrinogen concentrate administration was not significantly different between the groups (P=0.89). Tranexamic acid was not administered.
The significant reduction in allogeneic blood product requirements during surgical burn wound excision is a prospective proof of concept that a bleeding management algorithm based on thromboelastometry is efficacious. Hypofibrinogenaemia and hyperfibrinolysis are not significant pathomechanisms of bleeding in this setting and ROTEM(®) helps to avoid unnecessary interventions.
- Find related publications in this database (using NLM MeSH Indexing)
-
Adolescent -
-
Adult -
-
Aged -
-
Aged, 80 and over -
-
Algorithms -
-
Blood Transfusion -
-
Burns - surgery
-
Female -
-
Fibrinogen - therapeutic use
-
Hemorrhage - therapy
-
Humans -
-
Male -
-
Middle Aged -
-
Partial Thromboplastin Time -
-
Point-of-Care Systems -
-
Prospective Studies -
-
Thrombelastography -
- Find related publications in this database (Keywords)
-
blood
-
coagulation
-
fibrinogen
-
laboratory techniques and procedures
-
thrombelastography
-
wound and injuries
-