Müller, W; Horn, M; Fürhapter-Rieger, A; Kainz, P; Kröpfl, JM; Ackland, TR; Lohman, TG; Maughan, RJ; Meyer, NL; Sundgot-Borgen, J; Stewart, AD; Ahammer, H.
Body composition in sport: interobserver reliability of a novel ultrasound measure of subcutaneous fat tissue.
Br J Sports Med. 2013; 47(16):1036-1043 Doi: 10.1136/bjsports-2013-092233
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Müller Wolfram
Co-Autor*innen der Med Uni Graz
Ahammer Helmut
Fürhapter-Rieger Alfred
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Very low body mass, extreme mass changes, and extremely low per cent body fat are becoming increasingly common in many sports, but sufficiently reliable and accurate field methods for body composition assessment in athletes are missing. Nineteen female athletes were investigated (mean (SD) age: 19.5 (± 3.3) years; body mass: 59.6 (± 7.6) kg; height: 1.674 (± 0.056) m; BMI: 21.3 (± 2.3) kg/m(2)). Three observers applied diagnostic B-mode-ultrasound (US) combined with the evaluation software for subcutaneous adipose tissue measurements at eight ISAK sites (International Society for the Advancement of Kinanthrometry). Regression and reliability analyses are presented. US measurements and evaluation of subcutaneous adipose tissue (SAT) thicknesses (including fibrous structures: D(included); n=378) resulted in an SE of estimate SEE=0.60 mm, R(2)=0.98 (p<0.001), limit of agreement LOA=1.18, ICC=0.968 (0.957-0.977). Similar values were found for D(excluded): SEE=0.68 mm, R(2)=0.97 (p<0.001). D(included) at individual ISAK sites: at biceps, R(2)=0.87 and intraclass-correlation coefficient ICC=0.811 were lowest and SEE=0.79 mm was highest. Values at all other sites ranged from R(2): 0.94-0.99, SEE: 0.42-0.65 mm, and ICC: 0.917-0.985. Interobserver coefficients ranged from 0.92 to 0.99, except for biceps (0.74, 0.83 and 0.87). Evaluations of 20 randomly selected US images by three observers (D(included)) resulted in: SEE=0.15 mm, R(2)=0.998(p<0.001), ICC=0.997 (0.993, 0999). Subject to optimal choice of sites and certain standardisations, US can offer a highly reliable field method for measurement of uncompressed thickness of the SAT. High accuracy and high reliability of measurement, as obtained with this US approach, are essential for protection of the athlete's health and also for optimising performance.
Find related publications in this database (using NLM MeSH Indexing)
Body Composition - physiology
Female -
Gymnastics - physiology
Humans -
Muscle, Skeletal - anatomy & histology
Observer Variation -
Soccer - physiology
Sports Medicine - methods
Subcutaneous Fat - anatomy & histology
Young Adult -

Find related publications in this database (Keywords)
Body composition methodology
Weight loss
Assessing validity and reliability of test of physiological parameters
Elite performance
Ultrasound