Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Shah, AJ; Hocini, M; Xhaet, O; Pascale, P; Roten, L; Wilton, SB; Linton, N; Scherr, D; Miyazaki, S; Jadidi, AS; Liu, X; Forclaz, A; Nault, I; Rivard, L; Pedersen, ME; Derval, N; Sacher, F; Knecht, S; Jais, P; Dubois, R; Eliautou, S; Bokan, R; Strom, M; Ramanathan, C; Cakulev, I; Sahadevan, J; Lindsay, B; Waldo, AL; Haissaguerre, M.
Validation of novel 3-dimensional electrocardiographic mapping of atrial tachycardias by invasive mapping and ablation: a multicenter study.
J Am Coll Cardiol. 2013; 62(10):889-897 Doi: 10.1016/j.jacc.2013.03.082 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Scherr Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial tachycardias (AT). Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations. Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-à-vis subsequent invasive mapping and successful ablation. Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively. This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Find related publications in this database (using NLM MeSH Indexing)
Aged -
Body Surface Potential Mapping - methods
Catheter Ablation - methods
Electrocardiography - methods
Female -
Female -
Heart Atria - physiopathology
Humans -
Male -
Middle Aged -
Prospective Studies -
Tachycardia, Supraventricular - diagnosis
Tachycardia, Supraventricular - physiopathology
Tachycardia, Supraventricular -

Find related publications in this database (Keywords)
ablation
atrial tachycardia
electrocardiomapping
noninvasive mapping
© Med Uni GrazImprint