Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Dirks, V; Prêtre, R; Knirsch, W; Valsangiacomo Buechel, ER; Seifert, B; Schweiger, M; Hübler, M; Dave, H.
Modified Blalock Taussig shunt: a not-so-simple palliative procedure.
Eur J Cardiothorac Surg. 2013; 44(6):1096-1102 Doi: 10.1093/ejcts/ezt172 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Schweiger Martin
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Thirty-two consecutive isolated modified Blalock Taussig (BT) shunts performed in infancy since 2004 were reviewed and analysed to identify the risk factors for shunt intervention and mortality. Sternotomy was the only approach used. Median age and weight were 10.5 (range 1-74) days and 2.9 (1.9-4.4) kg, respectively. Shunt palliation was performed for biventricular hearts (Tetralogy of Fallot/double outlet right ventricle/transposition of great arteries_ventricular septal defect_pulmonary stenosis/pulmonary atresia_ventricular septal defect/others) in 21, and univentricular hearts in 11, patients. Hypoplastic left heart syndrome patients were excluded. Two procedures required cardiopulmonary bypass. Median shunt size was 3.5 (3-4) mm and median shunt size/kg body weight was 1.2 (0.9-1.7) mm/kg. Reduction in shunt size was necessary in 5 of 32 (16%) patients. Three of 32 (9%) patients died after 3 (1-15) days due to cardiorespiratory decompensation. Lower body weight (P = 0.04) and bigger shunt size/kg of body weight (P = 0.004) were significant risk factors for mortality. Acute shunt thrombosis was observed in 3 of 32 (9%), none leading to death. Need for cardiac decongestive therapy was associated with univentricular hearts (P < 0.001), bigger shunt size (P = 0.054) and longer hospital stay (P = 0.005). Twenty-eight patients have undergone a successful shunt takedown at a median age of 5.5 (0.5-11.9) months, without late mortality. Palliation with a modified BT shunt continues to be indicated despite increased thrust on primary corrective surgery. Though seemingly simple, it is associated with significant morbidity and mortality. Effective over-shunting and acute shunt thrombosis are the lingering problems of shunt therapy.
Find related publications in this database (using NLM MeSH Indexing)
Blalock-Taussig Procedure - adverse effects
Body Weight -
Female -
Heart Defects, Congenital - surgery
Humans -
Infant -
Infant, Newborn -
Male -
Palliative Care - methods
Retrospective Studies -
Risk Factors -
Sternotomy -
Thoracotomy -

Find related publications in this database (Keywords)
Modified Blalock Taussig shunt
Palliation
Mortality
Cyanotic heart disease
© Med Uni GrazImprint