Mylonas, G; Prskavec, M; Baradaran-Dilmaghani, R; Karnik, N; Buehl, W; Wirtitsch, M; .
Effect of a Single-Piece and a Three-Piece Acrylic Sharp-Edged IOL on Posterior Capsule Opacification.
Curr Eye Res. 2013; 38(1):86-90
Doi: 10.3109/02713683.2012.717242
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Wirtitsch Matthias
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Background: To compare the intensity of posterior capsule opacification (PCO) between two intraocular lenses (IOLs) of the same optic material, but with different haptic design (1-piece vs. 3-piece). Methods: This prospective intraindividual controlled cohort study comprised eighty eyes of 40 patients with bilateral age-related cataract. Each patient received a Polylens Y10 (Polytech, Germany) 1-piece IOL in 1 eye and a Polylens Y30 (Polytech, Germany) 3-piece IOL in the contralateral eye. The IOL type in the first operated eye was randomly assigned before patient recruitment. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for regeneratory PCO. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software. Results: The Polylens Y10 (1-piece) group showed significantly higher regeneratory and fibrotic PCO scores 1 year after surgery in subjective slitlamp evaluation, however not with objective evaluation using automated image-analysis software. Subjective PCO assessment resulted in a mean PCO score (scale = 0-10) of 1.6 in the Polylens Y10 group and 0.6 in the Polylens Y30 group at 1 year (p < 0.05). The mean automated image-analysis software PCO score was 1.5 in the Polylens Y10 group and 0.9 in the Polylens Y30 group (p = 0.6). Conclusion: Both investigated IOLs showed good clinical performance regarding PCO, BCVA and IOL-centration. The Polylens Y10 IOL showed slightly more regeneratory PCO than the 3-piece acrylic IOL 1 year after surgery.
- Find related publications in this database (using NLM MeSH Indexing)
-
Acrylates -
-
Aged -
-
Cataract - physiopathology
-
Cataract Extraction -
-
Female -
-
Follow-Up Studies -
-
Humans -
-
Hydrophobic and Hydrophilic Interactions -
-
Lenses, Intraocular -
-
Male -
-
Posterior Capsule of the Lens - pathology
-
Postoperative Complications - prevention & control
-
Prospective Studies -
-
Prosthesis Design -
-
Treatment Outcome -
-
Visual Acuity -
- Find related publications in this database (Keywords)
-
1-piece IOL
-
3-piece IOL
-
Cataract surgery
-
Intraocular lens
-
Posterior capsule pacification