Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Henrich, PB; Valmaggia, C; Lang, C; Priglinger, SG; Haritoglou, C; Strauss, RW; Cattin, PC.
Contrast recognizability during brilliant blue G - and heavier-than-water brilliant blue G-assisted chromovitrectomy: a quantitative analysis.
Acta Ophthalmol. 2013; 91(2):e120-e124
Doi: 10.1111/aos.12005
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Strauß Rupert
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- . Purpose: To evaluate the potential of heavier-than-water brilliant blue G (BBG-D20) to stain the internal limiting membrane (ILM) during chromovitrectomy. Methods: In a nonrandomized, prospective, clinical multicentre study, 71 consecutive chromovitrectomy interventions in 71 patients were analysed. During routine 23-gauge vitrectomy, conventional 0.25mg/ml BBG was employed in 21 and 0.25mg/ml BBG-D20 in 50 patients. All interventions were videotaped. Post-operatively, video frames were viewed and dye performance assessed subjectively and objectively. Main outcome measure was the chromaticity difference between the stained ILM and the unstained underlying retina, measured by means of an objective and quantitative analysis method to describe colour contrast strengths as they are perceived by the human eye. Results: Removal of the ILM was possible in all interventions without additional vital dyes. BBG-D20 readily sank to the retinal surface, while conventional BBG tended to swirl up throughout the vitreous cavity. Conventional BBG was removed either with active suction or with a flute needle. Brilliant blue G-D20 needed to be whirled up from the retinal surface with a flute needle before aspiration. Objective chromaticity measurements yielded a mean chromaticity score of 7.98 for BBG-D20 and 6.51 for BBG (p=0.09). Conclusions: Brilliant blue G-D20 readily sinks to the retinal surface after injection and can be conveniently removed with a flute needle or active suction during chromovitrectomy. Based on the premises of the chromaticity measurements in this study, BBG's ILM staining capacity was not significantly improved through the recent revision its preparation, although a tendency towards slightly improved contrasts between the ILM and the underlying retina was observed.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aged -
-
Aged, 80 and over -
-
Basement Membrane - pathology
-
Deuterium Oxide - adverse effects Deuterium Oxide - diagnostic use
-
Epiretinal Membrane - diagnosis Epiretinal Membrane - surgery
-
Female -
-
Humans -
-
Indicators and Reagents -
-
Male -
-
Middle Aged -
-
Prospective Studies -
-
Retinal Diseases - surgery
-
Rosaniline Dyes - adverse effects Rosaniline Dyes - diagnostic use
-
Vitrectomy -
- Find related publications in this database (Keywords)
-
Brilliant blue G
-
chromodissection
-
chromovitrectomy
-
CIELAB
-
contrast recognizability
-
deuterium
-
internal limiting membrane
-
intraoperative efficacy