Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Oechsner, M; Muhlhausler, M; Ritter, CO; Weininger, M; Beissert, M; Jakob, PM; Beer, M; Hahn, D; Kostler, H.
Quantitative Contrast-Enhanced Perfusion Measurements of the Human Lung Using the Prebolus Approach
J Magn Reson Imaging. 2009; 30(1):104-111
Doi: 10.1002/jmri.21793
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Beer Meinrad
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Purpose: To investigate dynamic contrast-enhanced MRI (DCE-MRI) for quantification of pulmonary blood flow (PBF) and blood volume (PBV) using the prebolus approach and to compare the results to the global lung perfusion (GLP). Materials and Methods: Eleven volunteers were examined by applying different contrast agent doses (0.5, 1.0, 2.0. and 3.0 mL gadolinium diethylene triamine pentaacetic acid [Gd-DTPA]). using a saturation-recovery (SR) true fast imaging with steady precession (TrueFISP) sequence. PBF and PBV were determined for single bolus and prebolus. Region of interest (ROI) evaluation was performed and parameter maps were calculated. Additionally, cardiac output (CO) and lung volume were determined and GLP was calculated as a contrast agent-independent reference value. Results: The prebolus results showed good agreement with low-dose single-bolus and GLP: PBF (mean +/- SD in units of mL/minute/100 mL) = single bolus 190 +/- 73 (0.5-mL dose) and 193 +/- 63 (1.0-mL dose): prebolus 192 +/- 70 (1.0-2.0-mL dose) and 165 +/- 52 (1.0-3.0-mL dose); GLP (mL/minute/100 mL) = 187 +/- 34. Higher single-bolus resulted in overestimated values due to arterial input function (AIF) saturation. Conclusion: The prebolus approach enables independent determination of appropriate doses for AIF and tissue signal. Using this technique, the signal-to-noise ratio (SNR) from lung parenchyma can be increased, resulting in improved PBF and PBV quantification, which is especially useful for the generation of parameter maps.
- Find related publications in this database (using NLM MeSH Indexing)
-
Adult -
-
Blood Flow Velocity - physiology
-
Blood Volume - physiology
-
Cardiac Output - physiology
-
Contrast Media - administration and dosage
-
Dose-Response Relationship, Drug -
-
Female -
-
Gadolinium DTPA - administration and dosage
-
Humans -
-
Image Enhancement - methods
-
Lung - anatomy and histology Lung - blood supply Lung - physiology
-
Lung Volume Measurements - methods
-
Magnetic Resonance Imaging - methods
-
Male -
-
Pulmonary Circulation - physiology
- Find related publications in this database (Keywords)
-
lung
-
contrast-enhanced MRI
-
pulmonary perfusion
-
prebolus
-
global lung perfusion