Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Frings, A; Steinbrugger, I; Wissiak, E; Vidic, B; El-Shabrawi, Y; Ardjomand, N.
Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia.
Ophthalmologe. 2012; 109(6):591-594
Doi: 10.1007/s00347-012-2556-5
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Ardjomand Navid
-
Frings Andreas
- Co-authors Med Uni Graz
-
El-Shabrawi Yosuf
-
Steinbrugger Iris
-
Vidic Bertram
-
Wissiak Elfriede
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Based on previous data on single-piece and three-piece intraocular lenses (IOLs) there is no evidence for significant differences in decentration, tilt and refractive shift. The purpose of the current study was to compare single-piece and three-piece IOLs in patients with high axial myopia. A total of 68 eyes of 50 patients with high axial myopia (axis length a parts per thousand yenaEuro parts per thousand 28.00 mm) with and without cataract who underwent complication-free phacoemulsification and IOL implantation were retrospectively examined. To compare single-piece and three-piece IOLs, the patients were retrospectively grouped depending on IOL type: group 1 acrylic single-piece IOL (n = 37; ACR6D SE, Corneal, France) and group 2 acrylic three-piece IOL with fixed haptic frame (n = 31; AF-1 UY, Hoya, Japan). Patient files were analyzed regarding best spectacle-corrected visual acuity (BSCVA), refractive predictability and stability. In this study the mean BSCVA was determined as 0.22 +/- 0.12 logMAR and 0.13 +/- 0.11 logMAR 6 months postoperatively for the ACR6D SE group and the AF-1 UV group, respectively (p = 0.09). Refractive predictability was less accurate in the ACR6D SE (+ 1.75 +/- 2.2 dpt) compared to the AF-1 UV (-aEuro parts per thousand 0.37 +/- 1.1) treated eyes (p = 0.001). Refractive stability, defined as the difference in diopters between the first week and the sixth month after surgery, resulted in + 0.40 +/- 1.7 dpt and -0.16 +/- 1.2 dpt for the ACR6D SE and the AF-1 UV, respectively (p = 0.022). The three-piece AF-1 UV showed satisfactory refractive predictability and stability in patients with high axial myopia. The ACR6D SE has a high refractive unpredictability and should not be used in eyes with high axial myopia.
- Find related publications in this database (using NLM MeSH Indexing)
-
Adult -
-
Aged -
-
Equipment Failure Analysis -
-
Humans -
-
Lenses, Intraocular -
-
Male -
-
Middle Aged -
-
Myopia - complications Myopia - diagnosis Myopia - rehabilitation
-
Prosthesis Design -
-
Refractive Errors - diagnosis Refractive Errors - rehabilitation
-
Treatment Outcome -
-
Visual Acuity -