Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Sadoghi, P; Leithner, A; Weber, P; Friesenbichler, J; Gruber, G; Kastner, N; Pohlmann, K; Jansson, V; Wegener, B.
Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study.
BMC Musculoskelet Disord. 2011; 12(13-14):142-142 Doi: 10.1186/1471-2474-12-142 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Sadoghi Patrick
Co-Autor*innen der Med Uni Graz
Friesenbichler Jörg
Gruber Gerald
Kastner Norbert
Leithner Andreas
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Background: Low-contact-stress (LCS) mobile-bearing total knee arthroplasty (TKA) (Johnson & Johnson, New Brunswick, NJ; previously: DePuy, Warsawa, USA) provides excellent functional results and wear rates in long-term follow-up analyses. Radiological analysis shows radiolucent lines (RLL) appearing immediately or two years after primary implantation, indicative of poor seat. Investigations proved RLL to be more frequent in uncemented TKA, resulting in a consensus to cement the tibial plateau, but their association with clinical findings and patients discomfort and knee pain is still unknown. Methods: 553 patients with 566 low-contact-stress (LCS) total knee prostheses were screened for continuous moderate knee pain. We compared tibial stress shielding classified by Ewald in patients suffering from pain with a matched, pain-free control group on blinded X-rays. We hypothesized a positive correlation between pain and radiolucency and higher frequency of such radiolucent lines in the most medial and most lateral zones of the tibial plateau. Results: Twenty-eight patients suffered from knee pain in total. Radiolucencies were detected in 27 of these cases and in six out of 28 matched controls without knee pain. We could demonstrate a significant correlation of knee pain and radiolucencies, which appeared significantly more frequently in the outermost zones of the tibial plateau. Conclusion: Our findings suggest that radiolucent lines, representing poor implant seat, about the tibial plateau are associated with knee pain in LCS patients. Radiolucencies are observed more often in noncemented LCS, and cementing the tibial plateau might improve implant seat and reduce both radiolucent lines and associated knee pain.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Age Factors -
Aged -
Aged, 80 and over -
Arthroplasty, Replacement, Knee - adverse effects
Case-Control Studies -
Female -
Follow-Up Studies -
Humans -
Knee Prosthesis - adverse effects
Linear Models -
Male -
Middle Aged -
Multivariate Analysis -
Osteoarthritis, Knee - physiopathology
Prosthesis Failure - adverse effects
Retrospective Studies -
Sex Factors -
Single-Blind Method -
Stress, Mechanical -

Find related publications in this database (Keywords)
Arthroplasty
low-contact-stress
mobile-bearing
radiolucent lines
knee pain
© Med Uni Graz Impressum