Friesenbichler, J; Maurer-Ertl, W; Sadoghi, P; Lovse, T; Windhager, R; Leithner, A.
Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.
Int Orthop. 2012; 36(3):539-544
Doi: 10.1007/s00264-011-1317-4
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Führende Autor*innen der Med Uni Graz
-
Friesenbichler Jörg
-
Maurer-Ertl Werner
- Co-Autor*innen der Med Uni Graz
-
Leithner Andreas
-
Lovse Thomas
-
Sadoghi Patrick
-
Windhager Reinhard
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Purpose The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty. Methods Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS). Results Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025). Conclusion The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.
- Find related publications in this database (using NLM MeSH Indexing)
-
Adolescent -
-
Adult -
-
Aged -
-
Aged, 80 and over -
-
Arthroplasty, Replacement, Knee - adverse effects Arthroplasty, Replacement, Knee - instrumentation Arthroplasty, Replacement, Knee - methods
-
Chromium - blood
-
Cobalt - blood
-
Female -
-
Humans -
-
Ions -
-
Knee Prosthesis -
-
Male -
-
Metals - blood
-
Middle Aged -
-
Molybdenum - blood
-
Prosthesis Design -
-
Prosthesis Failure - adverse effects
-
Surface Properties -
-