Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Etter, KE; Goswami, N; Sharp, MK.
Modelling of cardiovascular response to graded orthostatic stress: role of capillary filtration.
Eur J Clin Invest. 2011; 41(8): 807-819. Doi: 10.1111/j.1365-2362.2010.02466.x
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Goswami Nandu
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND:   Of the many possible factors that may contribute to orthostatic intolerance, the loss of circulating blood because of capillary filtration is one of the few that can explain the gradual decline of arterial pressure during stand tests. This study used a computer model to investigate the relative importance of haemodynamic parameters, including capillary filtration, as potential contributors to orthostatic intolerance. Simulated orthostatic tolerance times were compared to previous experiments combining head-up tilt and lower body negative pressure graded orthostatic stress, which provided haemodynamic data, in particular haematocrit measurements that allowed subject-specific modelling of capillary transport. MATERIALS AND METHODS:   The cardiovascular system was simulated using a seven-compartment model with measured heart rate, stroke volume, total peripheral resistance, mean arterial pressure and haematocrit data for 12 subjects. Simulations were controlled by decreasing the total blood volume at the measured rates of capillary filtration until cerebral pressure dropped below a threshold for consciousness. Predicted times to syncope were compared to actual times to presyncope, and sensitivity of arterial pressure and cardiac output to independent system parameters were determined. RESULTS:   There was no statistical difference in modelled times to syncope and actual times to presyncope. Both arterial pressure and cardiac output were most sensitive to total blood volume and least sensitive to caudal compliance parameters. CONCLUSIONS:   The feasibility of subject-specific simulations of cardiovascular response to orthostatic stress was demonstrated, providing stronger evidence that capillary filtration is a prominent mechanism in causing orthostatic intolerance. These results may have clinical and spaceflight applications. © 2011 The Authors. European Journal of Clinical Investigation © 2011 Stichting European Society for Clinical Investigation Journal Foundation.
Find related publications in this database (using NLM MeSH Indexing)
Capillaries - physiology
Capillary Permeability - physiology
Cardiovascular System - physiopathology
Cerebrovascular Circulation - physiology
Computer Simulation -
Head-Down Tilt - physiology
Humans -
Lower Body Negative Pressure -
Mathematics -
Models, Cardiovascular -
Orthostatic Intolerance - physiopathology
Space Flight -
Time Factors -

Find related publications in this database (Keywords)
Capillary filtration
cardiovascular modelling
lower body negative pressure
orthostatic intolerance
stand test
© Med Uni Graz Impressum