Medizinische Universität Graz - Research portal
Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Jenks, JD; Prattes, J; Frank, J; Spiess, B; Mehta, SR; Boch, T; Buchheidt, D; Hoenigl, M.
Performance of the Bronchoalveolar Lavage Fluid Aspergillus Galactomannan Lateral Flow Assay With Cube Reader for Diagnosis of Invasive Pulmonary Aspergillosis: A Multicenter Cohort Study.
Clin Infect Dis. 2021; 73(7):e1737-e1744
Doi: 10.1093/cid/ciaa1281
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Hönigl Martin
- Co-authors Med Uni Graz
-
Frank Johanna
-
Prattes Jürgen
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- BACKGROUND: The Aspergillus Galactomannan Lateral Flow Assay (LFA) is a rapid test for the diagnosis of invasive aspergillosis (IA) that has been almost exclusively evaluated in patients with hematologic malignancies. An automated digital cube reader that allows for quantification of results has recently been added to the test kits. METHODS: We performed a retrospective multicenter study on bronchoalveolar lavage fluid (BALF) samples obtained from 296 patients with various underlying diseases (65% without underlying hematological malignancy) who had BALF galactomannan (GM) ordered between 2013 and 2019 at the University of California, San Diego, the Medical University of Graz, Austria, and the Mannheim University Hospital, Germany. RESULTS: Cases were classified as proven (n = 2), probable (n = 56), putative (n = 30), possible (n = 45), and no IA (n = 162). The LFA showed an area under the curve (AUC) of 0.865 (95% confidence interval [CI] .815-.916) for differentiating proven/probable or putative IA versus no IA, with a sensitivity of 74% and a specificity of 83% at an optical density index cutoff of 1.5. After exclusion of GM as mycological criterion for case classification, diagnostic performance of the LFA was highly similar to GM testing (AUC 0.892 vs 0.893, respectively). LFA performance was consistent across different patient cohorts and centers. CONCLUSIONS: In this multicenter study the LFA assay from BALF demonstrated good diagnostic performance for IA that was consistent across patient cohorts and locations. The LFA may serve a role as a rapid test that may replace conventional GM testing in settings where GM results are not rapidly available.
- Find related publications in this database (Keywords)
-
hematologic malignancy
-
intensive care unit
-
respiratory diseases
-
solid organ transplant recipients
-
autoimmune diseases